The objective of this study was to develop and validate a new ion-pair reversed phase high performance liquid chromatographic method on a standard C18-type stationary phase with UV detection for the analysis of the recent two-drugs combination sacubitril/valsartan in tablets
The mobile phase consisted of a mixture of 45% of 10-3 M of cetyltrimethylammonium bromide (cetrimide) as the ion-pairing agent and 55% acetonitrile. The method validation was based on linearity, accuracy, precision, robustness and specificity
This method exhibits good linearity and accuracy with mean recovery values between 95.0–105.0%, precision with relative standard deviations of the calculated concentrations less than 5.0% and specificity in the presence of degradation products
These results indicates that the proposed method is simple and applicable for the separation and determination of sacubitril, valsartan combination in tablets and could be a relevant method to implement in quality control laboratories

 